OFFICE / COMMERCIAL BUILDINGS

USDA-ARS-MWA/NATIONAL SOIL TILTH LABORATORY,
Ames
,
Iowa
 |
Pre-design,
design, bid and construction administration for roof replacement.
2005
|
FRIEDRICH CONSTRUCTION COMPANY / MUNN LUMBER COMPANY,
Ames
,
Iowa
 |
Design footings for addition of display area, break
room, window repair room and conference room, 2005
|
USDA-ARS-MWA / NATIONAL SOIL TILTH LABORATORY,
Ames
,
Iowa
 |
Pre-design, design, bid and construction administration for replacement of
atrium panels. 2005
|
PORK TECHNOLOGIES, INC.,
Ames
,
Iowa
 |
Expert witness on hog confinement structure litigation, 2002
|
R.E. PEDROTTI CO., Inc.,
Mission
Kansas
 |
Complete engineered drawings for a Trylon T600-64 tower with concrete
foundation, 2002
|
USDA/NATIONAL ANIMAL DISEASE CENTER,
Ames
,
Iowa
Water Tower Renovation, 2001
 |
Development of schematic and preliminary plans and estimate for cost of
construction
|
USDA/NATIONAL SOIL TILTH LABORATORY,
Ames
,
Iowa
Security Access Control System, Phases I, II, III and IV.
2001 - 2004
 |
Bidding drawings and specifications for upgrade of
the existing security and access control systems.
|
USDA/PLANT INTRODUCTION FACILITY at
Iowa
State
University
,
Ames
,
Iowa
Machine Shed Addition, 2001
 |
Design, bid
document production, bid administration and construction observation.
|
Seed Storage Cooler, 2001
 |
Plans
and specifications for a 20’ x 50’ cooler and support, including fire
suppression system
|
JANICE ELIAS, Shelby, Ohio
Flour mill evaluation, 2001
 | Evaluate potential renovating of existing flour mill
into an apartment complex.
|
NATIONAL SOIL TILTH LABORATORY, Ames, Iowa
Conference Room Expansion, 2000
 |
Combine two existing rooms into one sate of the air audio/visual conference room, including interior finishes, data/voice and audio/video communications, satellite feeds, distance learning and video conferencing, sprinkler layout, electrical remodel and lighting design.
|
USDA-ARS-MWA, NATIONAL ANIMAL DISEASE CENTER, Ames, Iowa
Security Fencing and Telecommunications Improvements, 1999
 |
Addition of security chain link fencing with horizontal roller gates operated by dual card readers and proximity loop. Replacement and upgrade of existing twisted pair communication system with fiber optics and category 5 twisted pair. Upgrade of existing Johnson Controls NCUs
and security system.
|
IOWA STATE UNIVERSITY, Madrid, Iowa
Bilsland Swine Breeding Farm, 1995/96.
 |
A 1,600 square feet, Office Complex including a men's and women's shower In/Out facility with a break room and conference room.
|
WOODLAND FARMS, Story City, Iowa
Foundation Design: Warehouse, 1995.
 |
Design of a 22,500 square foot warehouse concrete foundation with a dock load-out area.
|
CENTRAL IA AGRI-SYSTEMS, Nevada, Iowa
Concrete Plan and Foundation: Office/Shop, 1995.
 |
Design of a 4,000 square foot concrete plan with column's and base pad for steel building frames.
|
UNIVERSITY OF MINNESOTA, Becker, Minnesota
Sand Plains Research Farm, 1992.
 |
Drawings and Specifications for a 2,400 square foot post frame seed sample preparation facility.
|
UNIVERSITY OF MINNESOTA, Grand Rapids, Minnesota
North Central Experiment Station, 1992
 |
Drawings and Specifications for a 3,600 square foot field crop laboratory with lab rooms, offices, meeting room, and a machinery storage area.
|
UNIVERSITY OF MINNESOTA, Morris, Minnesota
West Central Experiment Station.
 |
Drawings and Specifications for a 6,500 square foot agronomy research facility complete with labs, computer room, offices, and machinery storage area.
|
GEORGE A. ROLFES CO., Boone, Iowa
Baghouse Support Tower Design Review, 1991.
 |
Design analysis of proposed structural steel support tower and concrete foundation for dust collection baghouse unit.
|
CARL AND CAROL JACOBSON, Ames, Iowa
Residence Addition, 1991.
 |
Structural design and details for post-supported room addition to second story above grade.
|
STOKELY USA/KNUTSON CONSTRUCTION, Ackley, Iowa
Processing Building, 1991.
 |
Design of foundation and pre-cast concrete wall and mezzanine floor system for pre-engineered steel canning plant structure. 11,500 square feet.
|
KAPPA DELTA SORORITY/FRIEDRICH CONSTRUCTION, Ames, Iowa
Header Design, 1991.
 |
Site observation and design of header and column support system for basement level of 3-story building.
|
ACKLEY-GENEVA COMMUNITY SCHOOLS, Ackley, Iowa
Pre-engineered Steel Roof Replacement, 1991.
 |
Design of pre-engineered roof system to replace rubber roof on grade school and administration building. 15,800 square feet.
|
CARGILL INC./KNUTSON CONSTRUCTION, Iowa Falls, Iowa
Feed Processing Building Foundation, 1991.
 |
Concrete foundation design for 32 foot by 32 foot by four story pre-engineered steel building to enclose feed grinding and processing equipment.
|
STOKELY USA/KNUTSON CONSTRUCTION, Ackley, Iowa
Canning Plant Warehouse Foundation Design, 1990.
 |
Design of drawings of foundation for 204 foot by 300 foot by 42 foot eave height pre-engineered steel building including loading docks.
|
STOKELY USA, Ackley, Iowa
Structural Evaluation of Wood Canning Plant Building, 1990.
 |
Site observations, analysis, report and recommendations for future use or replacement of wood and masonry building used to house canning equipment.
|
STORY CONSTRUCTION/AMES RACQUET AND FITNESS CLUB, Ames, Iowa
Foundation System and Energy Review, 1990.
 |
Design of concrete foundation system for 120 foot by 104 foot by 16 foot eave height pre-engineered steel building addition for two tennis courts. Energy Code review
|
MIDLAND BIOPRODUCTS CORPORATION, Boone Iowa
Laboratory Hood Exhaust System, 1990.
 |
Design of duct exhaust system for laboratory fume hoods.
|
CENTRAL IOWA AGRI-SYSTEMS/MIDLAND BIOPRODUCTS CORP., Boone, Iowa
Foundation Design and Energy Review, 1990.
 |
Design of concrete foundation system for 100 foot by 152 foot office and laboratory building including loading docks and fascia system. Energy code review and certification of design compliance with state energy code.
|
SIEDELMANN CONSTRUCTION, Ames, Iowa
Foundation and Certification for USDA Entomology Building, 1990.
 |
Design of concrete foundation system for 40 foot by 105 foot by 20 foot eave height pre-engineered steel building. Structural review of wood floor system for mezzanine level.
|
FRIEDRICH CONSTRUCTION/WYLIE OPTICAL, Knoxville, Iowa
Optical Retail Center, 1990.
 |
Bored caisson and concrete grade beam foundation system and miscellaneous structural components for 4,100 square foot retail building.
|
ENERCEPT, INC., Evergreen, Minnesota
St. Paul’s Lutheran Church, 1990.
 |
Structural design review of roof and wall pre-fabricated panel systems.
|
|